MDF-U5312-R910x910
MDf-U5412-R

-30°C Upright Freezers

Biomedical Freezers with Panasonic refrigeration systems

Panasonic MDF series biomedical freezers are designed for short- or intermediate-term storage at temperatures as low as -30°C. Constructed with high-performance laboratory and clinical-grade refrigeration systems, these freezers are used in medical, biotechnology and industrial labs for storage of blood components, enzymes, culture media, reagents, specimens and vaccines.

    Main Features:

  • Optimum Storage Capabilities
  • Panasonic Designed Compressor
  • Microprocessor Controls
  • Superior Temperature Uniformity
  • Safety and Alarm Features
  • Environmentally Friendly

Optimum Storage Capabilitiesgroupofresearchers

Panasonic MDF series biomedical freezers are designed for short or intermediate-term storage at temperatures as low as -30°C. Constructed with high-performance laboratory and clinical-grade refrigeration systems, these freezers are used in clinical, biotechnology and industrial labs for storage of biologics, enzymes, culture media, reagents and specimens.

Uniformity

Uniformity temperature are maintained throughout the chamber using shelf freezing construction.

GreenHandsMicroprocessor Controls

Comprehensive set-point, alarm, monitoring and diagnostic functions are maintained by a Panasonic-built microprocessor controller with digital display of all input/output function.

Panasonic-Designed Refrigeration

Panasonic designed compressors are specifically for storage applications in a laboratory environment.

Environment-Friendly

HFC refrigerant R-404A is environment friendly and offers superb performance. A pre-coated metal body design causes less environmental damage than outer paint coating.

 

Safety and Alarms

TesttubeswithResearcher

  • Alarm and Recording system
  • High and low temperature alarm (± 5°C to ± 15°C, adjustable)
  • Power failure alarm
  • Remote alarm contact
  • Self diagnostics error message to direct you to the problem
  • Balance hinge door stops at any angle from 35° to 90° for convenience and safety
  • Optional LabAlert wireless Cloud/App based monitoring system available

Enzyme and Biologics : Preservation (Manual Defrost Models)

Uniform temperatures are maintained throughout the chamber using shelf freezing construction. Since there is no defrost cycle, the inner chamber temperature offers outstanding uniformity and stability without temperature spikes. Standard door lock for an independent padlock ensure extra safety.

Panasonic’s freezing coils in the shelf offers superb uniformity and exceptional temperature recovery due to the expanded surface area offered by the shelf freezing design.

No chamber fan or heaters. Natural convection inside the chamber offers tight uniformity due to the shelf freezing construction.

 
ModelMDF-U5312-PA
Temperature Setpoint Range-20°C to -30°C, with memory backupConstruction Two doors, two chambers
Exterior Dimensions (w x f-b x h)31.7" x 30.4" x 70.9" (804 x 772 x 1802 mm)Interior Dimensions (w x f-b x h)25.9" x 23.9" x 50.1" (658 x 607 x 1272 mm)
Capacity17.0 cu. ft. (482 liters)Cooling Performance-30°C (1/2h chamber air temperature; ambient temperature 35°C, no load)
Control Range-20°C to -30°C with memory backupDefrost SystemManual, defrost button on display
Top6 medium baskets (3 fixed evaporator shelves)Bottom4 large baskets (1 evaporator shelf and bottom)
Access ports30 mm diameter, rearCooling systemHermetic rotary compressor, ½ HP
RefrigerantR-404A (HFC)Visual and Audible Alarm systemHigh/low temperature alarm (SV ±5°C to ±15°C adjustable with ring -back function), Power failure, Remote alarm contacts (N.O./N.C.)
CalibrationZero adjustment via control panelElectrical Requirements115V, 60 Hz, 1 phase, 2.1 amps running, NEMA 5-15P plug
Net Weight295 lbs. (134 kg.)Shipping Weight320 lbs. (137 kg.)
SecurityDisplay Keylock, Keyed outer doors, Standard paddlock hasp per doorStorage ( Top Shelf)6 medium bins (3 fixed evaporator shelves)
Storage (Bottom Shelf)4 large bins (1 evaporator shelf and bottom)AlarmsHigh/low temperature alarm (SV ±5oC to ±15oC adjustable with ring-back function); Power Failure; Remote alarm contacts (N.O./N.C.)