In Research, Precision is Everything

Learn how our cell culture incubators can help you.

ico1
H2O2 Decontamination

Finishes in just 3 hrs compared to 12-24 hrs for high heat sterilization.

ico2
Dual Infrared (IR2) Sensor

Provides rapid CO2 recovery in as little as 2 minutes without overshoot.

ico3
InCu-saFe®

A copper alloy interior surface that acts as natural germicidal protection without corrosion

Choose the right incubator for your needs:

CellIQ CO2
Series

  • ico11

    Size:
    5.8 cu. ft.

  • ico10

    Contamination Control:
    Sterisonic H2O2 technology with active background contamination control (SafeCell UV and inCu-saFe) prevents any contaminant growth

  • ico11

    Interior Surface:
    inCu-Safe is an enriched stainless steel alloy interior surface, which provides natural germicidal protection without any rust or corrosion

  • ico12

    CO2 Control:
    Dual detector infrared (IR2) sensors provide quick recovery in under 2 mins after a door opening

  • ico13

    Temperature Uniformity:
    Patented Direct Heat and Air system with microprocessor controls provides uniform and consistent environment within the chamber

CellIQ Multi-Gas Series

  • ico11

    Size:
    6 cu. ft.

  • ico10

    Contamination Control:
    Sterisonic H2O2 technology with active background contamination control (SafeCell UV and inCu-saFe) prevents any contaminant growth

  • ico11

    Interior Surface:
    inCu-Safe is an enriched stainless steel alloy interior surface, which provides natural germicidal protection without any rust or corrosion

  • ico12

    CO2 Control:
    Dual detector infrared (IR2) sensors provide quick recovery in under 2 mins after a door opening

  • ico13

    Temperature Uniformity:
    Patented Direct Heat and Air system with microprocessor controls provides uniform and consistent environment within the chamber

CytoGrow Optimal Series

  • ico11

    Size:
    6 or 7.6 cu. ft.

  • ico10

    Contamination Control:
    Active background contamination control is provided through inCu-saFe interiors and an optional addition of SafeCell UV

  • ico11

    Interior Surface:
    inCu-Safe is an enriched stainless steel alloy interior surface, which provides natural germicidal protection without any rust or corrosion

  • ico12

    CO2 Control:
    Dual detector infrared (IR2) sensors (for 7.6 cu. ft.) or thermal conductivity (TC) sensors (for 6 cu. ft.)

  • ico13

    Temperature Uniformity:
    Patented Direct Heat and Air system with microprocessor controls provides uniform and consistent environment within the chamber

CytoGrow Compact Series

  • ico11

    Size:
    1.7 cu. ft.

  • ico10

    Contamination Control:
    Active background contamination control is provided through inCu-saFe interiors and an optional addition of SafeCell UV

  • ico11

    Interior Surface:
    inCu-Safe is an enriched stainless steel alloy interior surface, which provides natural germicidal protection without any rust or corrosion

  • ico12

    CO2 Control:
    Thermal conductivity (TC) sensors maintain CO2 at desired levels throughout the chamber after door openings

  • ico13

    Temperature Uniformity:
    Patented Direct Heat and Air system with microprocessor controls provides uniform and consistent environment within the chamber

CytoGrow Reach-In Series

  • ico11

    Size:
    30.1 cu. ft.

  • ico10

    Contamination Control:
    Active background contamination control is provided through inCu-saFe interiors and an optional addition of SafeCell UV

  • ico11

    Interior Surface:
    inCu-Safe is an enriched stainless steel alloy interior surface, which provides natural germicidal protection without any rust or corrosion

  • ico12

    CO2 Control:
    Dual detector infrared (IR2) sensors provide quick recovery in under 2 mins after multiple door openings

  • ico13

    Temperature Uniformity:
    Patented Direct Heat and Air system with microprocessor controls provides uniform and consistent environment within the chamber